YANG Fengjuan, CHEN Hua, CAI Yi, et al., “A 3D-PSF Space Size Selection Method Based on Inflection Point,” Chinese Journal of Electronics, vol. 26, no. 1, pp. 160-165, 2017, doi: 10.1049/cje.2016.11.012
Citation: YANG Fengjuan, CHEN Hua, CAI Yi, et al., “A 3D-PSF Space Size Selection Method Based on Inflection Point,” Chinese Journal of Electronics, vol. 26, no. 1, pp. 160-165, 2017, doi: 10.1049/cje.2016.11.012

A 3D-PSF Space Size Selection Method Based on Inflection Point

doi: 10.1049/cje.2016.11.012
Funds:  This work is supported by the National Natural Science Foundation of China (No.61164019) and the Guangxi Natural Science Foundation (No.2012GXNSFAA053216).
More Information
  • Corresponding author: CHEN Hua (corresponding author) was born in 1958. He received the Ph.D. degree in optical engineering from Beijing Institute of Technology. He is now a master's supervisor in Guangxi University. His research interests include biological image processing and photoelectric imaging technology. (Email:chenhua_cn@163.com)
  • Received Date: 2014-12-26
  • Rev Recd Date: 2015-08-12
  • Publish Date: 2017-01-10
  • In the three-dimensional microscopic biological image restoration processing of digital confocal microscopy, the selection of three-Dimensional Point spread function (3D-PSF) space size determines the restoration effect and restoration time. Based on 3D-PSF double funnel-shaped structure and analyzing the relationship of 3D-PSF space size to the image restoration effect and restoration time, it proposed the comprehensive image restoration evaluation criteria based on restoration efficiency, and also proposed the 3D-PSF selection method based on restoration efficiency curve inflection point. Three groups of 3D-PSF with different layer distances were used for image restoration experiments, the relationship between the 3D-PSF space sizes of different diameter and the image restoration effect and restoration time was built, and the restoration efficiency curve was obtained. Based on the curve inflection point, the selection of optional minimum space 3D-PSF and 3D-PSF was determined. Experimental results showed the method has good feasibility.
  • loading
  • M. Keuper, T. Schmidt, M. Temerinac-Ott, et al., "Blind deconvolution of widefield fluorescence microscopic data by regularization of the optical transfer function (OTF)", IEEE Conference on Computer Vision and Pattern Recognition, Vol.283, pp.2179-2186, 2013.
    Soulez. A. Ferréol, "Learn 2D, apply 3D" method for 3D deconvolution microscopy", IEEE 11th International Symposium on Biomedical Imaging (ISBI), Vol.6868060, pp.1075-1078, 2014.
    B. Dong, L. Shao, A.F. Franqi, et al., "Three-dimensional deconvolution of wide field microscopy with sparse priors:Application to zebrafish imagery", 22nd International Conference on Pattern Recognition (ICPR), Vol.159, pp.865-870, 2014.
    N. Chacko and M. Liebling, "Fast spatially variant deconvolution for optical microscopy via iterative shrinkage thresholding", IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), Vol.6854118, pp.2838-2842, 2014.
    P.A. Stoketh, "Properties of a defocused optical system", Optical. Soc. Amer., Vo1.59, No.10, 1314-1321, 1969.
    C. Preza and J.A. Conchello, "Depth-variant maximumlikelihood restoration for three dimensional fluorescence microscopy", J. Opt. Soc. Am. A, Vol.21, No.9, pp.1593-1601, 2004.
    C. Preza and A. Conchello J, "Image estimation accounting for point-spread function depth variation in three-dimensional fluorescence microscopy", Proceedings of SPIE, Vol.4964, pp.135-142, 2003.
    Teng Qizhi, Tao Qingchuan, Zhao Jia, et al., "Image estimation based on depth-variant imaging model", Computer Engineering and Applications, Vol.41, No.4, pp.32-34, 2005. (in Chinese)
    Lv Cheng-huai, He Xiao-hai, Tao Qing-chuan, et al., "Research on estimation algorithms for gaussian point spread function parameter in image restoration", Computer Engineering and Applications, Vol.43, No.10, pp.31-34, 2007. (in Chinese)
    Zhang Linlin, Jiang Zhiguo and Meng Rusong, "Point spread function estimation in microscopic image restoration", Eleventh China Stereology and Image Analysis Conference Proceedings, pp.332-336, 2006. (in Chinese)
    Tang Yuke, He Xiaohai and Tao Qingchuan, "Research on the point spread function of microscope based on the zernike polynomials", Acta Optica Sinica, Vol.29, No.1, pp.169-175, 2009. (in Chinese)
    He Xiaohai, Tao Qingchuan, Zhang Min, et al., "3-D EM image restoration based on wavelet transform", Computer Engineering and Applications, Vol.46, No.15, pp.169-171, 2010. (in Chinese)
    Chen Hua, Jin Weiqi, Wang Xia, et al., "Investigation about 3D microscopical image restoration and PSF", Optical Technique, Vol.32, No.3, pp.434-439, 2006. (in Chinese)
    Chen Hua, Yang Fengjuan and Cai Yi, "Relationship between point spread function layers and biological microscopic image restoration based on the same space size", Journal of Chemical and Pharmaceutical Research, Vol.6, No.3, pp.537-542, 2014.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (336) PDF downloads(467) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return